logo
project-banner
LOCATION

Mumbai, India

CLIENT

Manoj Infracon Pvt. Ltd.

PRODUCT USED

StrataWeb®

APPLICATION

Improving the load bearing capacity

About the project

The client desired an access road from the main artery road up to the container terminal, which is a distance of approximately 1.8 kilometres (about 1 mile). The subgrade of the road pavement was highly plastic and comprised of weak clayey soil.

Strata’s engineers suggested an innovative solution, using StrataWeb® geocells – a cost-effective, technically sound, and permanent solution for busy, heavy-duty access roads. The system incorporated StrataWeb® within the pavement section to reduce the bearing pressures onto the subsoil. This offered a leaner pavement cross-section that reduced material requirements by incorporating StrataWeb® facilitating speedy construction.

The design was for strengthening the pavement with a single layer of StrataWeb® geocells SW356-150 in-filled and topped with 150 mm of granular sub-base. 20,000 sqm. of StrataWeb® were used. StrataGrid™ was included in the pavement section to mobilize resistance to traction forces generated by vehicular movement.
 

The out-of-the-box solution resulted in an economical, fast and smooth construction process that ensured that bearing pressure was within safe limits.

image-1
image-2
image-3

Technical Drawing

Technical Drawing

CONSULTATION

From know-how to manufacture, installation and support.

Strata not only provides geotechnical products, but our team of 200+ engineers can help you with your turnkey project by supplying you with technical knowhow and support as to how our products can help you finish your projects in time while keeping costs down.

Send us your queries and we will get back to you with our expertise.

More success stories

Loop reinforced soil wall at Trichy

Loop reinforced soil wall at Trichy

The Design and Construction of the Reinforced Soil Wall (RS wall) in the Four Laning of Trichy section of NH-227, under the Bharatmala Pariyojana initiative, posed complex challenges that necessitated innovative solutions from Strata.

Read more
No concrete. Leaner pavement. Improved load bearing capacity.

No concrete. Leaner pavement. Improved load bearing capacity.

In any project, constructing on a weak subgrade is always a challenge. In this project, our client was confronted with a similar problem at their proposed container terminal in Kolkata, one of the four metro cities.

Read more
Protection for wind turbine generator footings for Erosion control

Protection for wind turbine generator footings for Erosion control

Owing to soil erosion because of wind and rainwater run-off, Suzlon was plagued with the exposure of foundations for its twenty wind energy generators (WTGs) at Mandsaur, Madhya Pradesh. Soil erosion can be severe during heavy rain or wind, and footings founded at shallow depths can get exposed. StrataWeb® geocells laid at the surface with appropriate in-fill protect against such erosion.

Read more