When a geogrid is specified for soil reinforcement, tensile strength is often one of the first properties considered. However, tensile strength is not necessarily the same in every direction.
A geogrid has a defined orientation, and its reinforcement characteristics can vary between the Machine Direction (MD) and Cross Machine Direction (CMD). Understanding these directions is important when assessing how a geogrid is intended to perform within a reinforced soil structure.
For PVA geogrids, this directional behaviour can be particularly relevant because different product configurations can provide different tensile capacities in MD and CMD, depending on the reinforcement requirements of the application.
What do MD and CMD mean?
The Machine Direction (MD) is the direction parallel to the direction of manufacture, while the Cross Machine Direction (CMD) is perpendicular to it.
For a roll of geogrid, MD generally corresponds to the direction along the length of the roll, while CMD runs across its width.
These terms are more than manufacturing terminology. They describe the orientation of the reinforcement and provide a basis for reporting directional tensile properties.
When a geogrid is tested for tensile performance, its properties can therefore be reported separately in MD and CMD.
Why does direction matter in reinforcement?
A geogrid develops tensile resistance through its interaction with the surrounding soil, by interface friction along its surfaces, as part of the soil reinforcement system. The direction in which that resistance is available needs to be considered alongside the geometry, loading conditions and reinforcement arrangement of the structure.
A geogrid should therefore not be viewed only through a single tensile strength value. Its directional properties can be equally important.
The relative tensile capacity in MD and CMD can depend on factors such as:
- Reinforcement arrangement
- Manufacturing process
- Grid geometry
- Product configuration
- Intended application
This is why understanding the directional properties of a geogrid provides a more complete picture of its reinforcement characteristics.
MD and CMD in PVA geogrids
StrataGrid™ SGV PVA geogrids are manufactured using high modulus polyvinyl alcohol (PVA) multifilament yarns arranged into a stable grid structure. The reinforcement yarns are encased in a durable polymer coating designed to help protect them against installation damage and environmental exposure in soil.
The product configuration determines how tensile capacity is distributed between MD and CMD.
The StrataGrid™ SGV range provides a useful illustration of this principle.
For example, the SGV 60 uniaxial geogrid has a characteristic tensile strength of:
- 60 kN/m in MD
- 20 kN/m in CMD
This demonstrates a higher tensile capacity in the machine direction.
By comparison, the SGV 100/100 biaxial configuration provides:
- 100 kN/m in MD
- 100 kN/m in CMD
This provides balanced characteristic tensile capacity in both directions.
The comparison highlights an important point: PVA geogrids are not defined simply by the polymer they use. The product configuration, reinforcement arrangement and directional properties determine how tensile capacity is distributed across the grid.
Is equal MD and CMD strength always required?
Not necessarily.
The required reinforcement characteristics depend on the application and the direction in which reinforcement forces are expected to develop.
For some applications, the primary reinforcement demand may be predominantly aligned with one direction. In others, the structure may require meaningful reinforcement in both directions.
For example, reinforced soil walls and steep slopes behave essentially in plane strain, with the principal reinforcement force acting perpendicular to the facing, so uniaxial reinforcement is normally appropriate. Embankments over soft soil need their primary strength across the embankment (perpendicular to its centre line), with the longitudinal direction checked separately, particularly near the embankment ends. Basal reinforcement spanning between pile caps or over potential voids, and base stabilisation beneath pavements and working platforms, generally require tensile resistance in two directions.
Therefore, equal MD and CMD tensile strength should not automatically be treated as a requirement for every project.
Instead, the directional properties of the selected geogrid should be considered alongside the design geometry, loading conditions, soil properties and reinforcement arrangement.
Understanding direction in reinforced soil structures
Consider a reinforced soil structure where geogrid layers extend from the facing into the reinforced fill. The geogrid should be oriented according to the design requirements so that its tensile resistance is available in the direction in which reinforcement forces are expected to develop. In reinforced soil walls and slopes, this means placing uniaxial geogrids with the MD perpendicular to the facing, extending into the reinforced fill over the full design length, with the CMD running parallel to the face.
This makes the orientation of the geogrid important during both design and installation.
A product with significantly different MD and CMD tensile capacities will provide a different reinforcement profile from one with similar capacity in both directions.
The engineer therefore needs to understand not only how much tensile strength the product provides, but also where that strength is available within the grid.
Directionality and geogrid selection
When evaluating a PVA geogrid, several questions can help establish whether its directional characteristics are appropriate for the application.
What are the MD and CMD tensile strengths?
Characteristic tensile strength provides the starting point for understanding the directional reinforcement capacity of the product.
For example, the SGV Uniaxial range provides different MD and CMD tensile capacities, while the SGV Biaxial range provides balanced tensile capacities in both directions.
What are the corresponding elongation characteristics?
Tensile strength should be considered together with the strain associated with that performance.
For the SGV range, elongation at characteristic strength is specified as ≤6% in both MD and CMD.
Understanding both tensile strength and elongation helps provide a more complete view of the reinforcement behaviour.
How will the geogrid be oriented?
The product should be installed according to the design intent. Its MD and CMD directions should therefore be clearly understood before placement.
On site, roll identification and orientation should be checked against the construction drawings, and uniaxial grids should not be rotated, substituted or joined without the designer's approval. Because simple overlaps do not transfer tensile load, the reinforcement should be continuous in the principal load direction over its full design length.
For products with different directional tensile capacities, correct orientation becomes particularly important.
What does the design require?
The required reinforcement capacity should come from the structural and geotechnical design rather than from the product's maximum characteristic tensile strength alone.
Product selection should account for the actual design requirements and the long-term performance of the reinforcement system.
PVA reinforcement across MD and CMD
The use of high modulus PVA multifilament yarns allows the reinforcement structure to be engineered for defined tensile characteristics in MD and CMD.
The SGV range demonstrates how product configuration can influence directional reinforcement.
Uniaxial configurations can provide greater tensile capacity in MD than CMD, as demonstrated by the SGV 60 with 60 kN/m in MD and 20 kN/m in CMD.
Biaxial configurations can provide balanced tensile capacity in both directions, as demonstrated by the SGV 100/100 with 100 kN/m in both MD and CMD.
The difference is not simply about having more or less tensile strength. It is about providing reinforcement characteristics suited to the intended application and design requirements.
MD and CMD should be considered alongside long-term performance
Directional tensile strength is only one part of geogrid selection.
For long-term reinforced soil structures, engineers also need to consider properties such as:
- Strain at characteristic strength
- Creep behaviour
- Long-term tensile capacity
- Installation effects
- Environmental exposure
- Soil-geogrid interaction
The tensile capacity considered for long-term design is lower than the characteristic tensile strength because design needs to account for factors such as creep, installation effects and environmental conditions.
The SGV datasheets, for example, specify a creep reduction factor of 1.33 at 20°C for a 120-year design life, alongside creep-limited strength values for the different product configurations.
This illustrates why characteristic tensile strength should not be viewed in isolation when assessing long-term reinforcement performance.
Conclusion
Geogrid reinforcement is directional by nature, and understanding that direction is an important part of selecting and installing a reinforcement product.
Machine Direction and Cross Machine Direction describe the orientation of the reinforcement and how its tensile capacity is distributed across the grid.
For PVA geogrids, product configuration can provide different directional reinforcement characteristics. Uniaxial products can offer higher tensile capacity in one direction, while biaxial products can provide more balanced capacity across both directions.
The SGV range demonstrates this distinction, from the SGV 60 with 60 kN/m in MD and 20 kN/m in CMD to the SGV 100/100 with 100 kN/m in both directions.
The key is therefore not to assume that one directional configuration is universally preferable. Instead, the MD and CMD properties of the selected geogrid should be evaluated against the design geometry, loading conditions, soil characteristics, reinforcement arrangement and long-term performance requirements.
For engineers and geosynthetic professionals, MD and CMD are therefore more than datasheet abbreviations. They are fundamental to understanding how a geogrid is configured, oriented and intended to perform within a reinforced soil system.